Power Supply

| Parameter | Value |

| --------------------------------------- | -------------------------- |

| Recommended nominal operating voltage | 14.4 V |

| Absolute maximum supply voltage | 18 V |

| Maximum system current | < 20 A |

| Internal fuse rating | 30 A |

| Recommended external vehicle fuse | 30 A |

| Reverse-polarity protection | Yes |

| Wake-up voltage threshold | 4.5 V ± 0.3 V |

| Standby current (KL30 only, KL15 off) | < 0.5 mA |

| Active operating current | Depends on connected loads |

The device is designed for permanent battery connection via fuse. Transmission

power sequencing and wake-up behaviour are managed internally. In USB-only mode

the device logic can be powered for configuration without vehicle power, and the

transmission power output remains disabled.

CAN Interfaces

| Parameter | Value |

| -------------------------- | -------------------------------------- |

| Number of interfaces | 4 (independent) |

| CAN FD transceiver | Microchip MCP2558FD |

| Supported standards | Classical CAN 2.0A / 2.0B, CAN FD |

| Classical CAN bitrate | up to 1 Mbps |

| CAN FD data-phase bitrate | up to 8 Mbps |

| Bitrate selection | Fully configurable |

| Termination | Switchable 120 Ω on each network |

| Physical interface | Differential pair per network (CANxH / CANxL) |

USB Interface

| Parameter | Value |

| ------------------------- | ---------------------------------------------- |

| Connector | USB-C |

| Speed | 480 Mbps (USB 2.0 High Speed) |

| Functions | Configuration, firmware updates, diagnostics, datalogging |

| Bus-powered configuration | Device logic can run from USB without vehicle power |

| CAN data access | candump-compatible CAN output over USB |

| Software | Dedicated IOcan configuration tool |

Analog Inputs

IOcan provides 11 analog inputs using resistor dividers that allow measurement of

automotive voltage ranges while protecting the internal ADC.

| Group | Channels | Typical range | Maximum measurable |

| ------------------ | -------- | ------------- | ------------------ |

| AN1–AN7 (0–12 V) | 7 | 0–12 V | 16 V |

| AN8–AN11 (0–5 V) | 4 | 0–5 V | 6 V |

Selected channels also support additional operating modes:

  • digital input mode

  • analog-switch / resistor-ladder mode (several buttons on one pin)

  • frequency input mode

Typical applications: ignition and switch signals, digital signals from ECUs,

throttle-position sensors, pressure sensors, and position sensors. See

Configuration Concepts for how inputs are assigned and scaled.

Frequency Inputs

| Parameter | Value |

| ---------------- | -------------------------------------- |

| Number of inputs | 4 (shared with selected analog inputs) |

| Signal types | square wave, hall-effect, ECU pulse outputs |

| Typical uses | engine speed, wheel speed, vehicle speed |

Signal conditioning and scaling are configurable in software.

Sensor Supply

| Output | Voltage | Maximum current | Purpose |

| --------- | ------- | --------------- | ------------------------------- |

| SENSOR5V | 5 V | 0.5 A | Powering external sensors |

| sGND | — | — | Dedicated sensor ground reference |

Using the dedicated sensor ground improves measurement accuracy and reduces noise.

Digital Outputs

| Parameter | Value |

| ----------------- | ----------------------------- |

| Number of outputs | 5 |

| Maximum current | 0.9 A per output |

| Output type | Low-side driver |

| Shared with | Selected analog input pins |

Typical applications: relay control, indicator outputs, and actuator control.

Output behaviour is fully configurable.

Transmission Power and Wake-up

| Function | Specification |

| --------------------------- | -------------------------------- |

| Transmission power output | Integrated semiconductor relay (KL30B) |

| Relay rated current | 15 A |

| Transmission wake-up output | Dedicated |

All transmission power control and wake-up signalling is handled directly by the

device. External relays are not required, and internal logic ensures correct

startup and shutdown sequencing.

Power Monitoring

IOcan can measure the transmission's current draw, supporting system monitoring,

diagnostics, and safety/fault detection.

Connector

| Main connector | TE Connectivity Superseal 1.0, 26-pin, 2-row |

Pin assignments and wiring details are documented in CAN Gateway Pinout.

Environmental and Mechanical

| Parameter | Value |

| ------------------- | --------------- |

| Physical dimensions | To be specified |

| Weight | To be specified |

IOcan is designed for automotive environments. Proper wiring and grounding are

required for reliable operation:

  • twisted-pair wiring for CAN networks

  • short CAN stubs

  • 120 Ω termination at both ends of the bus

  • properly crimped terminals (soldering is discouraged — flux residue causes wires to corrode and stiffen)

This device controls part of the powertrain. Take great care when wiring the

device and the transmission.

Summary

| Feature | Specification |

| ------------------------ | --------------------------------- |

| Supply (nominal / max) | 14.4 V / 18 V |

| CAN interfaces | 4 × CAN FD (CAN 2.0B compatible) |

| Analog inputs | 11 (7 × 0–12 V, 4 × 0–5 V) |

| Frequency inputs | 4 |

| Digital outputs | 5 × 0.9 A |

| Sensor supply | 5 V @ 0.5 A |

| Transmission power relay | 15 A (KL30B) |

| USB | USB-C, 480 Mbps |

| Main connector | TE Superseal 1.0, 26-pin |